A new method for measuring pistoning in lower limb prosthetic

Gholizadeh, H. and Abu Osman, Noor Azuan and Luviksdottir, A.G. and Kamyab, M. and Eshraghi, A. and Ali, S. and Wan Abas, Wan Abu Bakar (2011) A new method for measuring pistoning in lower limb prosthetic. In: 5th Kuala Lumpur International Conference on Biomedical Engineering, BIOMED 2011, Held in Conjunction with the 8th Asian Pacific Conference on Medical and Biological Engineering, APCMBE 2011, 2011, Kuala Lumpur.

[img]
Preview
PDF (A new method for measuring pistoning in lower limb prosthetic)
A_New_Method_for_Measuring_Pistoning_in_Lower_Limb_Prosthetic.pdf - Other

Download (217kB)
Official URL: http://www.scopus.com/inward/record.url?eid=2-s2.0...

Abstract

The quality of suspension in lower limb prosthetics has significant role in amputee's satisfaction. Good suspension lessens the pistoning movement of the residual limb inside the prosthetic socket. A number of methods are used for measuring pistoning; however most of them are difficult to be performed inside the prosthetic clinic and by every prosthetist. The purpose of this study was to introduce a new simple method for measuring pistoning in Transtibial prosthesis in static position. This method was developed in-house at Össur for the first time. In this study we used this technique to measure pistoning between socket and liner in three subjects. The result showed that this method can be an alternative method for measuring pistoning. Moreover, that makes it simple for prosthetists to test pistoning in the clinic and is a safe method for the subject. © 2011 Springer-Verlag.

Item Type: Conference or Workshop Item (Paper)
Funders: UNSPECIFIED
Additional Information: Conference code: 85436 Export Date: 24 February 2014 Source: Scopus Language of Original Document: English Correspondence Address: Gholizadeh, H.; Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Jalan Lembah Pantai, Kuala Lumpur, Malaysia; email: gholizadeh@um.edu.my References: Kristinsson, �., The ICEROSS concept: A discussion of a philosophy (1993) Prosthet Orthot Int, 17 (1), pp. 49-55; Isozaki, K., Hosoda, M., Masuda, T., Morita, S., CAD/CAM Evaluation of the fit of trans-tibial sockets for trans-tibial amputation stumps (2006) Journal of Medical and Dental Sciences, 53 (1), pp. 51-56. , http://lib.tmd.ac.jp/jmd/5301/07isozaki.pdf; Legro, M., Reiber, G., Del Aguila, M., Issues of importance reported by persons with lower limb amputations and prostheses (1999) J Rehabil Res Dev, 36 (3), pp. 155-163; Newton, R., Morgan, D., Schreiber, M., Radiological evaluation of prosthetic fit in below-the-knee amputees (1988) Skeletal Radiol, 17 (4), pp. 276-280; Sanders, J.E., Karchin, A., Fergason, J.R., Sorenson, E.A., A noncontact sensor for measurement of distal residual-limb position during walking (2006) Journal of Rehabilitation Research and Development, 43 (4), pp. 509-516. , http://www.vard.org/jour/06/43/4/pdf/sanders.pdf, DOI 10.1682/JRRD.2004.11.0143; Söderberg, B., Ryd, L., Persson, B., Roentgen stereophotogrammetric analysis of motion between the bone and the socket in a transtibial amputation prosthesis: A case study (2003) J Prosthet Orthot, 15 (3), pp. 95-99; Erikson, U., Lemperg, R., Roentgenological study of movements of the amputation stump within the prosthesis socket in below-knee amputees fitted with a PTB prosthesis (1969) Acta Orthopaedica, 40 (4), pp. 520-526; Grevsten, S., Erikson, U., A roentgenological study of the stumpsocket contact and skeletal displacement in the PTB-Suction Prosthesis (1975) Ups J Med Sci, 80 (1), pp. 49-57; Lilja, M., Johansson, T., Oberg, T., Movement of the tibial end in a PTB prosthesis socket: A sagittal X-ray study of the PTB prosthesis (1993) Prosthetics and Orthotics International, 17 (1), pp. 21-26; Narita, H., Yokogushi, K., Shi, S., (1997) Prosthet Orthot Int, 21 (3), pp. 175-178; Convery, P., Murray, K.D., Ultrasound study of the motion of the residual femur within a trans-femoral socket during gait (2000) Prosthetics and Orthotics International, 24 (3), pp. 226-232; Murray, K.D., Convery, P., The calibration of ultrasound transducers used to monitor motion of the residual femur within a trans-femoral socket during gait (2000) Prosthetics and Orthotics International, 24 (1), pp. 55-62; Abu Osman, N., Spence, W.D., Solomonidis, S.E., Transducers for the determination of the pressure and shear stress distribution at the stump-socket interface of trans-tibial amputees (2010) P I Mech Eng B-J Eng, 224 (8), pp. 1239-1250
Uncontrolled Keywords: Liner Pistoning Suspension Transtibial prosthesis Weight bearing Alternative methods Lower limb Number of methods Prosthetic sockets Residual limb SIMPLE method Static positions Biomedical engineering Artificial limbs
Subjects: T Technology > T Technology (General)
T Technology > TA Engineering (General). Civil engineering (General)
Divisions: Faculty of Engineering
Depositing User: Mr Jenal S
Date Deposited: 10 Apr 2014 02:27
Last Modified: 07 Feb 2019 08:16
URI: http://eprints.um.edu.my/id/eprint/9531

Actions (login required)

View Item View Item