A fuzzy Based Under-Frequency Load Shedding Scheme for islanded distribution network connected with DG

Mokhlis, Hazlie and Laghari, J.A. and Bakar, A.H.A. and Karimi, M. (2012) A fuzzy Based Under-Frequency Load Shedding Scheme for islanded distribution network connected with DG. International Review of Electrical Engineering, 7 (4). pp. 4992-5000. ISSN 1827-6660,

Full text not available from this repository.
Official URL: http://www.google.com.my/url?sa=t&rct=j&q=&esrc=s&...

Abstract

The frequency of power system is very sensitive to load changing when operating in islanded mode. This may causes overloading or loss of generation cases. Under-Frequency Load Shedding (UFLS) Scheme is commonly applied to stabilize the frequency during these cases. Conventional UFLS scheme operates successfully in interconnected grid system and may not work well when applied to DG based system operating in islanded mode. This paper presents a new fuzzy logic based under-frequency load shedding scheme implemented on mini hydro type-DG operating in islanded mode. The proposed strategy is based on frequency, rate of change of frequency and load prioritization. In proposed UFLS scheme, a fuzzy logic load shedding controller (FLLSC) with Load Shed Controller Module (LSCM) is modelled. FLLSC measures amount of load to be shed and LSCM shed the respective load to stabilize frequency. The proposed scheme is validated on different event-based and response-based cases. Simulation results show that proposed scheme is effective in shedding optimal number of loads while stabilizing the frequency.

Item Type: Article
Funders: UNSPECIFIED
Additional Information: Export Date: 17 April 2013 Source: Scopus Language of Original Document: English Correspondence Address: Mokhlis, H.; Department of Electxical Engineering, Faculty of Engineering, University of Malaya, 50603 Kuala Lumpur, Malaysia References: Barker, P.P., de Mello, R.W., Determining the impact of distributed generation on power systems. I. Radial distribution systems (2000) IEEE Power Engineering Society Summer Meeting, 3, pp. 1645-1656. , in; Davda, A., Desai, M.D., Parekh, B.R., Assessment of Reduction in Losses by Distributed Generation Penetration in a Radial Network: A Case Study (2011) International Review on Modelling and Simulations (IREMOS), 4 (1 PART A), pp. 120-124. , February 2011; Mohamad, H., Mokhlis, H., Bakar, A.H.A., Ping, H.W., A review on islanding operation and control for distribution network connected with small hydro power plant (2011) Renewable and Sustainable Energy Reviews, 15, pp. 3952-3962; Laaksonen, H., Kauhaniemi, K., Voima, S., DG Unit Fault Behavior and Protection of LV Microgrid (2010) International Review on Modelling and Simulations (IREMOS), 3 (3), p. 353367. , June; Fereidouni, A.R., Nafisi, H., Garmrudi, M., Dezaki, H.H., The Effect of Distributed Generation in Distribution Network on Coordination of Protective Devices (2011) International Review on Modelling and Simulations (IREMOS), 4 (4 PART B), pp. 1773-1780. , August; IEEE Standard for Interconnecting Distributed Resources With Electric Power Systems (2003) IEEE Std 1547-2003, pp. 1-16. , IEEE Standard; IEEE Recommended Practice for Utility Interface of Photovoltaic (PV) Systems (2000) IEEE Std 9292000, pp. i. , IEEE Recommended Practice; Ding, X., Girgis, A.A., Optimal load shedding strategy in power systems with distributed generation (2001) IEEE Power Engineering Society Winter Meeting, 2, pp. 788-793. , in; Terzija, V.V., Koglin, H.J., Adaptive underfrequency load shedding integrated with a frequency estimation numerical algorithm (2002) Generation, Transmission and Distribution, 149, pp. 713-718. , IEE Proceedings-; Wahab, N.I.A., Mohamed, A., Transient Stability Emergency Control Using Generator Tripping Based on Tracking Area-Based Rotor Angle Combined with UFLS (2010) International Review of Electrical Engineering (IREE), 5 (2004 PART B), pp. 2317-2326. , October; Malekpour, A.R., Abbasi, A.R., Seifi, A.R., A New Coordinated Approach to Load Shedding in Integrated Transmission and Distribution Systems (2010) International Review of Electrical Engineering (IREE), 5 (3 PART B), pp. 1172-1182. , June; Anderson, P.M., Mirheydar, M., An adaptive method for setting underfrequency load shedding relays (1992) IEEE Transactions on Power Systems, 7, pp. 647-655; Shokooh, F., Dai, J.J., Shokooh, S., Tastet, J., Castro, H., Khandelwal, T., Donner, G., Intelligent Load Shedding (2011) Industry Applications Magazine, IEEE, 17, pp. 44-53; Jung, J., Chen-Ching, L., Tanimoto, S.L., Vittal, V., Adaptation in load shedding under vulnerable operating conditions (2002) IEEE Transactions on Power Systems, 17, pp. 1199-1205; Wang, P., Billinton, R., Optimum load-shedding technique to reduce the total customer interruption cost in a distribution system (2000) Generation, Transmission and Distribution, IEE Proceedings-, 147, pp. 51-56; Hazarika, D., Sinha, A.K., Method for optimal load shedding in case of generation deficiency in a power system (1998) International Journal of Electrical Power & Energy Systems, 20, pp. 411-420; Luan, W.P., Irving, M.R., Daniel, J.S., Genetic algorithm for supply restoration and optimal load shedding in power system distribution networks (2002) Generation, Transmission and Distribution, IEE Proceedings-, 149, pp. 145-151; Mahat, P., Zhe, C., Bak-Jensen, B., Underfrequency Load Shedding for an Islanded Distribution System With Distributed Generators (2010) IEEE Transactions on Power Delivery, 25, pp. 911-918; Aponte, E.E., Nelson, J.K., Time optimal load shedding for distributed power systems (2006) IEEE Transactions on Power Systems, 21, pp. 269-277; Prasetijo, D., Lachs, W.R., Sutanto, D., A new load shedding scheme for limiting underfrequency (1994) IEEE Transactions on Power Systems, 9, pp. 1371-1378; Girgis, A.A., Mathure, S., Application of active power sensitivity to frequency and voltage variations on load shedding (2010) Electric Power Systems Research, 80, pp. 306-310; Terzija, V.V., Adaptive underfrequency load shedding based on the magnitude of the disturbance estimation (2006) IEEE Transactions on Power Systems, 21, pp. 1260-1266; Mohd Zin, A.A., Mohd Hafiz, H., Aziz, M.S., A review of under-frequency load shedding scheme on TNB system (2003) National Proceedings. Power and Energy Conference, pp. 170-174. , PECon, in; Lukic, M., Kuzle, I., Tesnjak, S., An adaptive approach to setting underfrequency load shedding relays for an isolated power system with private generation (1998) 9th Mediterranean Electrotechnical Conference, MELECON, 2, pp. 1122-1125. , in; Kundur, P., (1994) Power System Stability and Control, , Mcgraw-Hill
Uncontrolled Keywords: Distributed generation (DG); Fuzzy logic load shedding controller (FLLSC); Load shed controller module (LSCM); Islanded distribution network; Power-system; Generation; Algorithm; Relays
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
T Technology > TK Electrical engineering. Electronics Nuclear engineering