Gaeid, K.S. and Ping, H.W. (2010) Induction motor fault detection and isolation through unknown input observer. Scientific Research and Essays, 5 (20). pp. 3152-3159. ISSN 1992-2248,

[img]
Preview
PDF
Khalaf_Salloum_Gaeid._Induction_motor_fault_detection_and_isolation_through.pdf - Published Version

Download (152kB)
Official URL: http://www.academicjournals.org/journal/SRE/articl...

Abstract

Unknown input observers (UIO) can be used in the model-based fault detection and isolation (FDI) schemes to reduce or almost eliminate the effect of unknown disturbances on the multi input multi output (MIMO) plant/system. In this paper, a new FDI of the MIMO system was carried out in as well as the design of many fault isolation banks of UIOs has been done. These banks are used to generate residuals that are insensitive to unknown disturbances or noise. To make sure best detection and isolation of the faults, these banks generate residuals, which are sensitive to only one fault. The fault in the actuator is detected and isolated with a lower false alarm rate effectively.

Item Type: Article
Funders: UNSPECIFIED
Uncontrolled Keywords: Fault detection and isolation; Induction motor; MIMO plant; Residuals; Unknown input observers
Subjects: T Technology > T Technology (General)
T Technology > TA Engineering (General). Civil engineering (General)
T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Faculty of Engineering
Depositing User: Mr Faizal 2
Date Deposited: 16 Jan 2015 02:32
Last Modified: 22 May 2017 07:58
URI: http://eprints.um.edu.my/id/eprint/12143

Actions (login required)

View Item View Item