The diagnostic performance of a single geneXpert MTB/RIF assay in an intensified tuberculosis case finding survey among HIV-infected prisoners in Malaysia

Al-Darraji, H.A.A. and Razak, H.A. and Ng, K.P. and Altice, F.L. and Kamarulzaman, A. (2013) The diagnostic performance of a single geneXpert MTB/RIF assay in an intensified tuberculosis case finding survey among HIV-infected prisoners in Malaysia. PLoS ONE, 8 (9). pp. 1-10. ISSN 1932-6203,

[img]
Preview
PDF
00000544_99566.pdf

Download (566kB)

Abstract

The new GeneXpert MTB/RIF assay (Xpert) offers accurate and rapid diagnosis of active TB, but its performance in improving case detection in high-transmission congregate settings has yet to be evaluated. We assessed the diagnostic accuracy of a single Xpert assay in an intensified case finding survey among HIV-infected prisoners in Malaysia. Methods: HIV-infected prisoners at a single site provided two early-morning sputum specimens to be examined using fluorescence smear microscopy, BACTEC MGIT 960 liquid culture and a single Xpert. The sensitivity,specificity, negative and positive predictive values of Xpert were calculated relative to gold-standard results using MGIT 960 liquid culture. Relevant clinical and demographic data were used to examine correlates of active TB disease. Results: The majority of enrolled subjects with complete data (N=125) were men (90.4%), age <40 years (61.6%) and had injected drugs (75.2%). Median CD4 lymphocyte count was 337 cells/μL (IQR 149-492); only 19 (15.2%) were receiving antiretroviral therapy. Of 15 culture-positive TB cases, single Xpert assay accurately detected only eight previously undiagnosed TB cases, resulting in a sensitivity, specificity, positive predictive value and negative predictive value of 53.3% (95% CI 30.12-75.2%), 100% (95% CI 96.6-100%), 100% (95% CI 67.56-100%) and 94.0% (95% CI 88.2-97.1%), respectively. Only 1 of 15 (6.7%) active TB cases was smear-positive. The prevalence (12%) of undiagnosed active pulmonary TB (15 of 125 prisoners) was high and associated with longer duration of drug use (AOR 1.14, 95% CI 1.03-1.26, for each year of drug use). Conclusions: Single Xpert assay improved TB case detection and outperformed AFB smear microscopy, but yielded low screening sensitivity. Further examination of the impact of HIV infection on the diagnostic performance of the new assay alongside other screening methods in correctional settings is warranted.

Item Type: Article
Funders: UNSPECIFIED
Subjects: R Medicine > R Medicine (General)
Divisions: Faculty of Medicine
Depositing User: Ms. Norhamizah Tamizi
Date Deposited: 16 Apr 2014 01:44
Last Modified: 05 Jul 2017 01:50
URI: http://eprints.um.edu.my/id/eprint/9588

Actions (login required)

View Item View Item