A large exposure to brucella melitensis in a diagnostic laboratory

Sam, I.C. and Karunakaran, R. and Kamarulzaman, A. and Ponnampalavanar, S. and Omar, S.F.S. and Ng, K.P. and Yusof, M.Y.M. and Hooi, P.S. and Jafar, F.L. and AbuBakar, Sazaly (2012) A large exposure to brucella melitensis in a diagnostic laboratory. Journal of Hospital Infection, 80 (4). pp. 321-325. ISSN 0195-6701, DOI https://doi.org/10.1016/j.jhin.2011.12.004.

[img] PDF
Sam-2012-A_large_exposure_to.pdf - Published Version
Restricted to Registered users only

Download (216kB) | Request a copy
Official URL: http://ac.els-cdn.com/S0195670111004609/1-s2.0-S01...

Abstract

Background: Brucella species are easily transmitted by aerosols and can be acquired in the laboratory. Aim: To report the management of a large exposure to Brucella melitensis that occurred over six days in a hospital diagnostic laboratory. Methods: Fifty-one exposed staff were managed according to Centers for Disease Control and Prevention guidelines. A further 96 non-exposed laboratory staff were tested for seroprevalence. Testing was carried out using the Brucella sp. serum agglutination test. Findings: Twenty-seven people had high-risk exposure and 24 had low-risk exposure. High-risk staff were offered post-exposure prophylaxis. Twelve (44.4) agreed to this, of whom eight (66.7) completed the course. Overall compliance with serological follow-up at baseline, 2, 4, 6 weeks and 8 months was 45.9. Despite this poor compliance there were no clinical brucellosis cases and no seroconversion in the 47.1 of staff tested at 8 months. Brucella sp. seroprevalence among all staff tested was 3/147 (2.0). Conclusion: Lack of experience with Brucella spp. and lack of policies for handling potentially hazardous organisms contributed to this prolonged exposure. As compliance with current recommendations may be poor, the optimum frequency of serological follow-up and target groups for prophylaxis should be reassessed. Laboratories in low- or non-endemic areas must prepare for potential isolation of Brucella spp. The impact of human brucellosis in Malaysia requires further study. (C) 2011 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

Item Type: Article
Funders: UNSPECIFIED
Additional Information: Sam, I-C. Karunakaran, R. Kamarulzaman, A. Ponnampalavanar, S. Omar, S. F. Syed Ng, K. P. Yusof, M. Y. Mohd Hooi, P. S. Jafar, F. L. AbuBakar, S.
Uncontrolled Keywords: Adolescent Antibodies, Bacterial/blood Attitude of Health Personnel Brucella melitensis/*isolation & purification Brucellosis/*prevention & control Female Humans *Laboratories, Hospital Malaysia *Occupational Exposure Post-Exposure Prophylaxis/methods
Subjects: R Medicine
Divisions: Faculty of Medicine
Depositing User: Miss Malisa Diana
Date Deposited: 12 Nov 2012 01:54
Last Modified: 13 Feb 2019 08:31
URI: http://eprints.um.edu.my/id/eprint/3916

Actions (login required)

View Item View Item