Validation of a simple extraction procedure for bisphenol A identification from human plasma

Wiraagni, Idha Arfianti and Mohd, Mustafa Ali and Abd Rashid, Rusdi and Haron, Didi Erwandi Mohamad (2019) Validation of a simple extraction procedure for bisphenol A identification from human plasma. PLoS ONE, 14 (10). e0221774. ISSN 1932-6203, DOI https://doi.org/10.1371/journal.pone.0221774.

Full text not available from this repository.
Official URL: https://doi.org/10.1371/journal.pone.0221774

Abstract

The general population is exposed to bisphenol A (BPA) orally, parenterally, transdermally, and environmentally as a result of the use of BPA in food packaging, plastics, and personal care products. The majority of the population nowadays (91–99%) has detectable levels of BPA inside their body. In this study, we successfully performed an inexpensive, rapid, and simple protein precipitation procedure for extraction of BPA from human plasma, followed by analysis by LC-MS/MS. This method was specifically developed for handling large numbers of samples with minimum cost and volume of sample. The developed method was accurate, precise, and reproducible for quantification of BPA from human plasma samples in the concentration range of 10–2000 ng/mL. The method was performed on samples from 150 healthy volunteers who were enrolled in the study. The mean of observed BPA level was 2.22 ± 9.91 ng/mL. Higher BPA levels were observed for females compare to that of males (p-value = 0.002), the BPA levels were higher in participants 33 years of age and older compared to those less than 33 years of age (p-value = 0.000), then the BPA levels higher in subjects with tap water as source of drinking (p-value = 0.005). This method may be valuable for general risk assessment of BPA for a large and varied population because of its efficiency and economical aspects. © 2019 Wiraagni et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Item Type: Article
Funders: UNSPECIFIED
Uncontrolled Keywords: accuracy; adult; calibration; chromatography by mobile phase; controlled study; drug blood level; drug cost; drug determination; drug efficacy; drug sensitivity; drug stability; economic aspect; female; human; human tissue; limit of detection; limit of quantitation; liquid chromatography; liquid liquid extraction; male; precipitation; quality control; reproducibility; risk assessment; sensitivity and specificity; sex difference; solid phase extraction; solvent extraction; standard; statistical significance; tandem mass spectrometry; validation process; volunteer
Subjects: R Medicine
Divisions: Faculty of Medicine
Depositing User: Ms. Juhaida Abd Rahim
Date Deposited: 02 Dec 2019 01:59
Last Modified: 02 Dec 2019 01:59
URI: http://eprints.um.edu.my/id/eprint/23171

Actions (login required)

View Item View Item