Jaddoa, M.F. and Jasim, Ali Abdulhadi and Razak, M.Z.A. and Harun, Sulaiman Wadi and Ahmad, Harith (2016) Highly responsive NaCl detector based on inline microfiber Mach–Zehnder interferometer. Sensors and Actuators A: Physical, 237. pp. 56-61. ISSN 0924-4247, DOI https://doi.org/10.1016/j.sna.2015.11.014.
Full text not available from this repository.Abstract
This paper details the fabrication and performance evaluation of a sodium chloride (NaCl) detector based on an inline microfiber Mach–Zehnder interferometer (IMMZI) that had been fabricated via a glass fiber processing system (Vytran GPX-3400). Spectral characteristics of IMMZIs possessing a variety of waist diameters and situated within assorted concentrations of NaCl solutions are also reported. An optimally high responsitivity to NaCl solutions of about 2913.7 nm per refractive-index unit (RIU) was exhibited by an IMMZI with a total length of 34 mm and a tapered waist diameter of 10 μm, in which the RI ranged from 1.31837 to 1.31928.
Item Type: | Article |
---|---|
Funders: | University of Malaya: UM.C/625/1/HIR/MOHE/SCI/01 and RU007/2015 |
Uncontrolled Keywords: | Microfiber; Inline microfiber Mach–Zehnder interferometer; Fiber optic sensor; Refractive index sensor |
Subjects: | Q Science > QC Physics T Technology > TK Electrical engineering. Electronics Nuclear engineering |