Soft storey buildings are characterized by having a storey which has a lot of open spaces. This soft storey creates a major weak point in an earthquake. Since soft stories are classically associated with retail spaces and parking garages, they are often on the lower stories of a building, which means that when they collapse, they can take the whole building down with them, causing serious structural damage which may render the structure totally unusable. In this study, efforts have been given to examine the effect of incorporation of isolator on the seismic behavior of buildings subjected to the appropriate earthquake for medium risk seismicity region. It duly ensures incorporating isolator with all relevant properties as per respective isolators along with its time period and damping ratio. Effort has also been made here to build up a relationship for increasing storey height and the changes for incorporating isolator with same time period and damping ratio for both lead rubber bearing (LRB) and high damping rubber bearing (HDRB). Dynamic analyses have been carried out using response spectrum and time history analysis. Behavioral changes of structural parameters are investigated. The study reveals that the values of structural parameters reduce a large amount while using isolator. However, LRB is found beneficial than HDRB. The structure experiences huge storey drift at the soft storey level that may be severe and cause immature failure. The amount of masonry infill is very vital for soft storey buildings as its decrement increases reasonable displacements.

Item Type: Article
Funders: UNSPECIFIED
Additional Information: Cited By (since 1996): 5 Export Date: 6 January 2013 Source: Scopus Language of Original Document: English Correspondence Address: Saiful Islam, A. B. M.; Department of Civil Engineering, University of Malaya, Kuala Lumpur, Malaysia; email: abm.saiful@gmail.com References: Ariga, T., Kanno, Y., Takewaki, I., Resonant behaviour of baseisolated high-rise buildings under long-period ground motions (2006) Struct. Des. Tall Special Build, 15, pp. 325-338; Balkaya, C., Kalkan, E., Nonlinear seismic response evaluation of tunnel form building structures (2003) Comput. Struct, 81, pp. 153-165; (1993) BNBC. Bangladesh: Housing and Building Research Institute, , Bangladesh National Building Code, Bangladesh Standard and Testing Institute; Baratta, A., Corbi, I., Optimal design of base-isolators in multistory buildings (2004) Comput. Struct, 82, pp. 2199-2209; Bhuiyan, A.R., Okui, Y., Mitamura, H., Imai, T., A rheology model of high damping rubber bearings for seismic analysis: Identification of nonlinear viscosity (2009) Int. J. Solids Struct, 46, pp. 1778-1792; Casciati, F., Hamdaoui, K., Modelling the uncertainty in the response of a base isolator (2008) Probabilistic Eng. Mech, 23, pp. 427-437; Chen, Y.Q., Constantinou, M.C., Use of Teflon sliders in a modification of the concept of soft first storey (1990) Eng. Struct, 12 (4), pp. 243-253; Chen, Y.Q., Constantinou, M.C., Use of Teflon sliders in a modification of the concept of soft first storey (1992) Constr. Build. Mater, 6, pp. 97-105; (2004) Linear and Nonlinear Static and Dynamic Analysis of Three-dimensional Structures Berkeley (CA): Computer & Structures, , CSI Computer & Structures Inc. SAP2000, Inc; Dall'asta, A., Ragni, L., Experimental tests and analytical model of high damping rubber dissipating devices (2006) Eng. Struct, 28, pp. 1874-1884; Dall'asta, A., Ragni, L., Nonlinear behavior of dynamic systems with high damping rubber devices (2008) Eng. Struct, 30, pp. 3610-3618; Deb, S., Seismic base isolation-an overview (2004) Curr. Sci, 87, pp. 1426-1430; di Egidio, A., Contento, A., Seismic response of a non-symmetric rigid block on a constrained oscillating base (2010) Eng. Struct, 32, pp. 3028-3039; Dicleli, M., Buddaram, S., Comprehensive evaluation of equivalent linear analysis method for seismic-isolated structures represented by sdof systems (2007) Eng. Struct, 29, pp. 1653-1663; Habibullah, A., (2005) SAP 2000, Static and Dynamic Finite Element Analysis of Structures, , Computers and Structures Inc., Berkeley, California; Hong, W., Kim, H., Performance of a multi-storey structure with a resilient-friction base isolation system (2004) Comput. Struct, 82, pp. 2271-2283; Hussain, R.R., Islam, A.B.M.S., Ahmad, S.I., (2010) Base Isolators As Earthquake Protection Devices In Buildings: VDM Publishing House Ltd, p. 140. , Benoit Novel, Simultaneously published in USA & U.K; Islam, A.B.M.S., (2009) Evaluation of Structural and Economic Implications of Incorporating Base Isolator As Earthquake Protection Device In Buildings In Dhaka Master's Thesis, , Dhaka, Bangladesh: Bangladesh Univ. Eng. Technol., (BUET); Islam, A.B.M.S., Ahmad, S.I., (2010) Isolation System Design For Buildings In Dhaka: Its Feasibility and Economic Implication, pp. 99-104. , Proc. Conf. Eng. Res. Innov. Educ. 11-13 January, Bangladesh, Sylhet; Islam, A.B.M.S., Ahmad, S.I., Al-Hussaini, T.M., (2010) Effect of Isolation On Buildings In Dhaka. 3rd International Earthquake Symposium, pp. 465-472. , BES. 5-6 March; Bangladesh, Dhaka; Islam, A.B.M.S., Ahmad, S.I., Jameel, M., Jumaat, M.Z., (2010) Seismic Base Isolation For Buildings In Regions of Low to Moderate Seismicity: A Practical Alternative Design. Practice Periodical On Structural Design and Const, , ASCE., DOI: 10.1061/(ASCE)SC.1943-5576.0000093; Islam, A.B.M.S., Ahmad, S.I., Jameel, M., Generation of Response Spectra Along With Time History for Earthquake in Dhaka for Dynamic Analysis of Structures (2010) SUST Stud, 14 (4), pp. 56-68; Islam, A.B.M.S., Jameel, M., Jumaat, M.Z., Seismic isolation in buildings to be a practical reality: Behaviour of structure and installation technique (2011) J. Eng. Technol. Res, 3 (4), pp. 99-117; Islam, A.B.M.S., Jameel, M., Jumaat, M.Z., Study on optimal isolation system and dynamic structural responses in multi-storey buildings (2011) Int. J. Phys. Sci, 6 (9), pp. 2219-2228; Ismail, M., Rodellar, J., Ikhouane, F., An innovative isolation device for aseismic design (2010) Eng. Struct, 32, pp. 1168-1183; Jangid, R.S., Optimum lead-rubber isolation bearings for near-fault motions (2007) Eng. Struct, 29, pp. 2503-2513; Kelly, T.E., (2001) Base Isolation of Structures: Design Guidelines, , Holmes Consulting Group Ltd; Kelly, T.E., Robinson, W.H., Skinner, R.I., Seismic Isolation for Designers and Struct (2006) Eng, , Robinson Seismic Ltd; Kilar, V., Koren, D., Seismic behaviour of asymmetric base isolated structures with various distributions of isolators (2009) Eng. Struct, 31, pp. 910-921; Kirac, N., Dogan, M., Ozbasaran, H., (2010) Failure of Weak Storey During Earthquakes, , Engineering Failure Analysis In Press; Komodromos, P., Simulation of the earthquake-induced pounding of seismically isolated buildings (2008) Comput. Struct, 86, pp. 618-626; Komodromos, P., Polycarpou, P., Papaloizou, L., Phocas, M., Response of seismically isolated buildings considering poundings (2007) Earthquake Eng. Struct. Dynam, 36, pp. 1605-1622; Lu, L.Y., Lin, G.L., Predictive control of smart isolation system for precision equipment subjected to near-fault earthquakes (2008) Eng. Struct, 30, pp. 3045-3064; Matsagar, V.A., Jangid, R.S., Influence of isolator characteristics on the response of base-isolated structures (2004) Eng. Struct, 26, pp. 1735-1749; Micheli, I., Cardini, S., Colaiuda, A., Turroni, P., Investigation upon the dynamic structural response of a nuclear plant on aseismic isolating devices (2004) Nuclear Eng. Des, 228, pp. 319-343; Mo, Y.L., Chang, Y.F., Application of base isolation concept to soft first storey build (1995) Comput. Struct, 55, pp. 883-896; Pocanschi, A., Phocas, M.C., Earthquake isolator with progressive nonlinear deformability (2007) Eng. Struct, 29, pp. 2586-2592; Polycarpou, P.C., Komodromos, P., Earthquake-induced poundings of a seismically isolated building with adjacent structures (2010) Eng. Struct, 32, pp. 1937-1951; Providakis, C.P., Effect of LRB isolators and supplemental viscous dampers on seismic isolated buildings under near-fault excitations (2008) Eng. Struct, 30, pp. 1187-1198; Sharma, A., Jangid, R., Behaviour of Base-Isolated Structures with High Initial Isolator Stiffness (2009) Int. J. Appl. Sci. Eng. Technol, p. 5; Spyrakos, C.C., Koutromanos, I.A., Maniatakis, C.A., Seismic response of base-isolated buildings including soil-structure interaction (2009) Soil Dyn. Earthquake Eng, 29, pp. 658-668; (1997) Earthquake Regulations For Seismic Isolated Structures, , Uniform Building Code, UBC, Whitter CA, USA; Wilbowo, A., Wilson, J.L., Lam, N.T.K., Gad, E.F., Collapse modeling analysis of a precast soft storey building in Australia (2010) Eng. Struct, 32, pp. 1925-1936; Yoshimura, M., Nonlinear analysis of a reinforced concrete building with a soft first storey collapsed by the 1995 Hyogoken- Nanbu earthquake (1997) Cem. Concrete Comp, 19, pp. 213-221
Uncontrolled Keywords: Base isolation, Base moment, Base shear, Failure prediction, Floor acceleration, Inertia force, Masonry infill, Rubber bearing, Soft storey, Storey drift.