Zaghlul, Nureen and Goh, Siew Li and Razman, Rizal and Danaee, Mahmoud and Chan, Chow Khuen (2023) Test-retest reliability of the single leg stance on a Lafayette stability platform. PLoS ONE, 18 (1). ISSN 1932-6203, DOI https://doi.org/10.1371/journal.pone.0280361.
Full text not available from this repository.Abstract
The validity and reliability of the Lafayette stability platform are well-established for double leg testing. However, no evaluation of single leg (SL) stance on the platform was discovered yet. Therefore, this study aimed to investigate the reliability of conducting the SL stance on the Lafayette platform. Thirty-six healthy and active university students (age 23.2 & PLUSMN; 3.2 years; BMI 21.1 & PLUSMN; 3.1 kg/m(2)) were tested twice, one week apart (week 1; W1, week 2; W2). They stood on their dominant leg with eyes-open (EO) and eyes-closed (EC) in random order. Three successful trials of 20 seconds each were recorded. The duration during which the platform was maintained within 0 & DEG; of tilt was referred to as time in balance (TIB). At all-time points, TIB was consistently longer in EO (EOW1: 17.02 & PLUSMN; 1.04s; EOW2: 17.32 & PLUSMN; 1.03s) compared to EC (ECW1: 11.55 & PLUSMN; 1.73s; ECW2: 13.08 & PLUSMN; 1.82s). A & PLUSMN;10 seconds difference was demonstrated in the Bland-Altman analysis in both EO and EC. Lower standard error of measurement (SEM) and coefficient of variation (CV) indicated consistent output. High intraclass correlation coefficient (ICC) values were seen between weeks (EO = 0.74; EC = 0.76) and within weeks (EOW1 = 0.79; EOW2 = 0.86; ECW1 = 0.71; ECW2 = 0.71). Although statistical measures (i.e., SEM, CV, and ICC) indicated good reliability of Lafayette for SL tasks, the wide agreement interval is yet to be clinically meaningful. Factors underlying the wide variation need to be identified before Lafayette is used for TIB assessment.
Item Type: | Article |
---|---|
Funders: | Universiti Malaya, Malaysia through the Postgraduate Research Grants (GPF007C-2019) ; (GPF026A-2019) |
Subjects: | R Medicine > R Medicine (General) T Technology > T Technology (General) |
Divisions: | Faculty of Engineering > Department of Biomedical Engineering Faculty of Medicine Faculty of Medicine > Social & Preventive Medicine Faculty of Sports and Exercise Science (formerly known as Centre for Sports & Exercise Sciences) |
Depositing User: | Ms. Juhaida Abd Rahim |
Date Deposited: | 17 Jul 2025 04:03 |
Last Modified: | 17 Jul 2025 04:03 |
URI: | http://eprints.um.edu.my/id/eprint/50924 |
Actions (login required)
![]() |
View Item |