Ghayeb, Haider Hamad and Razak, Hashim Abdul and Sulong, N. H. Ramli and Mo, Kim Hung and Abutaha, Fuad and Gordan, Meisam (2021) Performance of mechanical steel bar splices using grouted couplers under uniaxial tension. Journal of Building Engineering, 34. ISSN 2352-7102, DOI https://doi.org/10.1016/j.jobe.2020.101892.
Full text not available from this repository.Abstract
In this study, grouted couplers were used to connect steel bars as an alternative approach to the conventional steel bar lapping method. The aim is to avoid bar congestion problems and to reduce the required quantity of steel bars in order to achieve the development length in practice. Two categories of couplers, i.e., short-threaded grout coupler and long grout coupler, in nine groups as well as one group of deformed bars, were tested under uniaxial tension. In total, 30 samples (including three repeated samples in each group) were tested. The examined parameters were types of couplers, embedded bar length, and bar eccentricity. For the short-threaded grout couplers, the embedded bar length, which is equivalent to 8 times bar diameter with bar eccentricity equal to zero, exhibited the best performance in terms of strength, ductility, energy absorption, and failure mode, which is suitable to be used in the high seismic zone. Additionally, the short-threaded grout couplers with the embedded bar length equal to 7 times bar diameter and the long grout couplers that required embedded bar length that is equal to 8 times bar diameter, are suitable to be used in the low-to-medium seismic zone. Besides, the embedded bar length that is smaller than or equal to the 6 times bar diameter was not sufficient to be utilised in the short-threaded grout couplers and long grout couplers to resist the seismic load due to inadequate bar embedded length. Also, the predicted model is sufficient to estimate the ultimate tensile strength of the grouted couplers.
Item Type: | Article |
---|---|
Funders: | Faculty of Engineering, University of Malaya (UM) (PG199-2015B), Faculty of Engineering, University of Malaya (UM) (GPF071A-2018), Ministry of Higher Education (MOHE), Malaysia (PG199-2015B), Ministry of Higher Education (MOHE), Malaysia (GPF071A-2018), Halfen Moment Company Sdn Bhd |
Uncontrolled Keywords: | Bond-slip failure; Fracture failure; Grouted couplers; Mechanical splice; Precast connector; Uniaxial tensile test |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) |
Divisions: | Faculty of Engineering > Department of Civil Engineering |
Depositing User: | Ms Zaharah Ramly |
Date Deposited: | 10 Aug 2022 00:25 |
Last Modified: | 10 Aug 2022 00:25 |
URI: | http://eprints.um.edu.my/id/eprint/28440 |
Actions (login required)
View Item |