Modulation techniques to reduce leakage current in three-phase transformerless H7 photovoltaic inverter

Freddy, T.K.S. and Rahim, N.A. and Hew, W.P. and Che, H.S. (2015) Modulation techniques to reduce leakage current in three-phase transformerless H7 photovoltaic inverter. IEEE Transactions on Industrial Electronics, 62 (1). pp. 322-331. ISSN 0278-0046, DOI https://doi.org/10.1109/TIE.2014.2327585.

[img] PDF (Modulation Techniques to Reduce Leakage Current in Three-Phase Transformerless H7 Photovoltaic Inverter)
Modulation_Techniques_to_Reduce_Leakage_Current_in.pdf - Other
Restricted to Repository staff only

Download (2MB) | Request a copy
Official URL: http://ieeexplore.ieee.org/xpls/abs_all.jsp?arnumb...

Abstract

Recently, reduced common-mode voltage (CMV) pulsewidth modulation (RCMV-PWM) methods have been proposed to reduce the leakage current in three-phase transformerless photovoltaic (PV) systems. However, most of these studies only focus on leakage current elimination and neglect the overall performance of the PV systems on issues such as cost, voltage linearity, dc-link current ripples, and harmonic distortion. In this paper, a three-phase transformerless inverter, adapted from the single-phase H5 topology, is investigated. Since the H5 topology has been conventionally developed for a single-phase system, its adaptation to the three-phase system requires the development of corresponding three-phase modulation techniques. Hence, modulation techniques are proposed based on conventional PWM. The performances of the proposed PWM, in terms of CMV, leakage current, voltage linearity, output current ripples, dc-link current ripples, and harmonic distortion are studied and discussed via simulation and experiment. It is proven that the proposed topology is able reduce the leakage current without sacrificing the overall performance of the system.

Item Type: Article
Funders: Campus Network Smart Grid for Energy Security H-16001-00-D000032, Peruntukan Penyelidikan Pascasiswazah (PPP) PV105-2012A
Additional Information: Ax2ir Times Cited:0 Cited References Count:37
Uncontrolled Keywords: Common-mode voltage (CMV); Leakage current; Photovoltaic (PV) system; Transformerless; Common-mode voltage; Grid-connected inverter; PV system; PWM; Topologies
Subjects: T Technology > T Technology (General)
T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Faculty of Engineering
Depositing User: Mr Jenal S
Date Deposited: 01 Sep 2015 04:03
Last Modified: 30 Dec 2015 04:01
URI: http://eprints.um.edu.my/id/eprint/13865

Actions (login required)

View Item View Item