The thermoluminescence characteristics and the glow curves of Thulium doped silica fiber exposed to 10 MV photon and 21 MeV electron radiation

Alawiah, A. and Alina, M.S. and Bauk, S. and Abdul-Rashid, H.A. and Gieszczyk, W. and Noramaliza, M.N. and Mandiraji, G.A. and Tamchek, N. and Zulkifli, M.I. and Bradley, D.A. and Marashdeh, M.W. (2015) The thermoluminescence characteristics and the glow curves of Thulium doped silica fiber exposed to 10 MV photon and 21 MeV electron radiation. Applied Radiation and Isotopes, 98. pp. 80-86. ISSN 0969-8043, DOI https://doi.org/10.1016/j.apradiso.2015.01.016.

[img]
Preview
PDF (The thermoluminescence characteristics and the glow curves of Thulium doped silica fiber exposed to 10 MV photon and 21 MeV electron radiation)
The_thermoluminescence_characteristics_and_the_glow_curves_of_Thulium.pdf - Other

Download (1MB)
Official URL: http://www.sciencedirect.com/science/article/pii/S...

Abstract

The thermoluminescence (TL) glow curves and kinetics parameters of Thulium (Tm) doped silica cylindrical fibers (CF) are presented. A linear accelerator (LINAC) was used to deliver high-energy radiation of 21 MeV electrons and 10 MV photons. The CFs were irradiated in the dose range of 0.2-10 Gy. The experimental glow curve data was reconstructed by using WinREMS. The WinGCF software was used for the kinetic parameters evaluation. The TL sensitivity of Tm-doped silica CF is about 2 times higher as compared to pure silica CF. Tm-doped silica CF seems to be more sensitive to 21 MeV electrons than to 10 MV photons. Surprisingly, no supralinearity was displayed and a sub-linear response of Tm-doped silica CF was observed within the analyzed dose range for both 21 MeV electrons and 10 MV photons. The Tm-doped silica CF glow curve consists of 5 individual glow peaks. The Ea of peak 4 and peak 5 was highly dependent on dose when irradiated with photons. We also noticed that the electron radiation (21 MeV) caused a shift of glow peak by 7-13 degrees C to the higher temperature region compared with photons radiation (10 MV). Our Tm-doped fibers seem to give high TL response after 21 MeV electrons, which gives around 2 times higher peak integral as compared with 10 MV photon radiation. We concluded that peak 4 is the first-order kinetic peak and can be used as the main dosimetric peak of Tm-doped silica CF. (C) 2015 Elsevier Ltd. All rights reserved.

Item Type: Article
Funders: UNSPECIFIED
Additional Information: Alawiah, A Alina, M S Bauk, S Abdul-Rashid, H A Gieszczyk, W Noramaliza, M N Mahdiraji, G A Tamchek, N Zulkifli, M I Bradley, D A Marashdeh, M W eng England 2015/02/04 06:00 Appl Radiat Isot. 2015 Apr;98:80-6. doi: 10.1016/j.apradiso.2015.01.016. Epub 2015 Jan 23.
Uncontrolled Keywords: Sub-linearity, TL kinetic model, Kinetic parameters, Glow curve, Glow, peak, Sio2 optical-fibers, dosimeter, ge, irradiation, therapy,
Subjects: T Technology > T Technology (General)
T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Faculty of Engineering
Depositing User: Mr Jenal S
Date Deposited: 23 Jul 2015 00:36
Last Modified: 23 Jul 2015 00:36
URI: http://eprints.um.edu.my/id/eprint/13754

Actions (login required)

View Item View Item