Calculated parameters for the diagnosis of Wilson disease

Zulkufli, Nada Syazana and Sthaneshwar, Pavai and Chan, Wah-Kheong (2023) Calculated parameters for the diagnosis of Wilson disease. Singapore Medical Journal, 64 (3). pp. 188-195. ISSN 0037-5675, DOI https://doi.org/10.11622/smedj.2022019.

Full text not available from this repository.

Abstract

Introduction: The diagnosis of Wilson disease (WD) is plagued by biochemical and clinical uncertainties. Thus, calculated parameters have been proposed. This study aimed to: (a) compare the diagnostic values of non-caeruloplasmin copper (NCC), NCC percentage (NCC%), copper-caeruloplasmin ratio (CCR) and adjusted copper in WD; and (b) derive and evaluate a discriminant function in diagnosing WD.Methods: A total of 213 subjects across all ages who were investigated for WD were recruited. WD was confirmed in 55 patients, and the rest were WD free. Based on serum copper and caeruloplasmin values, NCC, NCC%, CCR and adjusted copper were calculated for each subject. A function was derived using discriminant analysis, and the cut-off value was determined through receiver operating characteristic analysis. Classification accuracy was found by cross-tabulation.Results: Caeruloplasmin, total copper, NCC, NCC%, CCR, adjusted copper and discriminant function were significantly lower in WD compared to non-WD. Discriminant function showed the best diagnostic specificity (99.4%), sensitivity (98.2%) and classification accuracy (99.1%). Caeruloplasmin levels <0.14 g/L showed higher accuracy than the recommended 0.20 g/L cut-off value (97.7% vs. 87.8%). Similarly, molar NCC below the European cut-off of 1.6 umol/L showed higher accuracy than the American cut-off of 3.9 umol/L (80.3% vs. 59.6%) (P < 0.001). NCC%, mass NCC, CCR and adjusted copper showed poorer performances.Conclusion: Discriminant function differentiates WD from non-WD with excellent specificity, sensitivity and accuracy. Performance of serum caeruloplasmin <0.14 g/L was better than that of <0.20 g/L. NCC, NCC%, CCR and adjusted copper are not helpful in diagnosing WD.

Item Type: Article
Funders: UNSPECIFIED
Uncontrolled Keywords: Caeruloplasmin; Discriminant function; Free copper; Non-caeruloplasmin copper; Wilson disease
Subjects: R Medicine > RB Pathology
Divisions: Faculty of Medicine > Medicine Department
Faculty of Medicine > Pathology Department
Depositing User: Ms. Juhaida Abd Rahim
Date Deposited: 24 Oct 2025 07:43
Last Modified: 24 Oct 2025 07:43
URI: http://eprints.um.edu.my/id/eprint/48371

Actions (login required)

View Item View Item