Feasibility study of a minibeam collimator design for a Co-60 gamma irradiator

Moradi, F. and Khandaker, M. U. and Abdul Sani, Siti Fairus and Uguru, E. H. and Sulieman, A. and Bradley, D. A. (2021) Feasibility study of a minibeam collimator design for a Co-60 gamma irradiator. Radiation Physics and Chemistry, 178 (SI). ISSN 0969-806X, DOI https://doi.org/10.1016/j.radphyschem.2020.109026.

Full text not available from this repository.

Abstract

Recently much attention has been paid to microbeam and minibeam irradiations, present interest focusing on their use in study of the behaviour of single cells, groups of cells, also their application in spatially fractionated radiotherapy. Synchrotrons are the most common source for microbeam radiotherapy (MRT), albeit limited in access and typically offering photon energies very much lower than familiar in the practice of conventional radiotherapy. In this study of feasibility, the design has been investigated of a collimator coupled to a conventional Co-60 gamma-irradiator sample chamber to produce a minibeam. MCNPX code Monte Carlo simulations were used to model a Gammacell 220 Co-60 irradiator with lead and tungsten collimators. The dose profile was evaluated in the absence and presence of the collimator, seeking to optimize collimator design. The results pertain to specific shapes of lead and tungsten collimators producing narrow (millimeter dimension) beams, sufficient in thickness but yet still fitting within the sample chamber, with a peak-to-valley dose ratio (PVDR) greater than 15. The beam size can be tailored with modification in the size of the perforated part, the collimator optimized to minimize the dose-rate at points away from the collimator centre. However the dose-rate at the centre is reduced to between 2 to 20% of that in the absence of collimator. The findings of this study encourage the development of minibeam collimator for gamma irradiators, useful for preclinical minibeam radiotherapy research in centres with little or no access to other appropriate sources.

Item Type: Article
Funders: UNSPECIFIED
Uncontrolled Keywords: Gammacell 220; Monte Carlo simulation; Minibeam; Collimator
Subjects: Q Science > QC Physics
Q Science > QD Chemistry
Divisions: Faculty of Science > Department of Physics
Depositing User: Ms Zaharah Ramly
Date Deposited: 12 Apr 2022 05:33
Last Modified: 12 Apr 2022 05:33
URI: http://eprints.um.edu.my/id/eprint/28351

Actions (login required)

View Item View Item