Abdul Hayei, Nur Ayman and Yahya, Noor Azlin and Safii, Syarida Hasnur and Saub, Roslan and Vaithilingam, Rathna Devi and Baharuddin, Nor Adinar (2021) Influence of scaler tip design on root surface roughness, tooth substance loss and patients’ pain perception: an in vitro and a randomised clinical trial. BMC Oral Health, 21 (1). p. 169. ISSN 1472-6831, DOI https://doi.org/10.1186/s12903-021-01540-0.
Full text not available from this repository.Abstract
Background: The influence of scaler tip design on root surface roughness, tooth substance loss and patients’ pain perception is investigated. Methods: This article was divided into the following parts: Part 1 Surface roughness and substance loss: an in vitro study, which involves intact extracted teeth sectioned and treated using a piezoelectric ultrasonic device (PM200 EMS Piezon, Switzerland) with a conventional scaler tip (FS-407) and a Perio Slim (PS) scaler tip (Perio Slim DS-016A). All sectioned samples for tooth surface roughness (n = 20) and tooth substance loss (n = 46) analyses were measured and compared using a 3D surface texture analyser and scanning electron microscope (SEM) respectively, at baseline and following scaling. Part 2 Pain Perception: a clinical study, which was a split mouth study design including 30 participants with gingivitis and/or mild chronic periodontitis; treated with supra-gingival scaling from teeth #13 to #23. Subjects were randomised to group A or group B. Group A was treated first with PS scaler tips, whereas group B was treated first with conventional scaler tips. Pain perception was recorded using the visual analogue scale (VAS). Results: In vitro study: both scaler tips caused significant reduction in root substance roughness after scaling (p < 0.05), but no significant difference between the two scaler tips (p > 0.05) was observed. The PS scaler tip caused statistically significantly less root substance loss (p < 0.05) when the initial thickness of the tooth was < 1000 µm. Clinical study: the participants reported significantly lesser pain score during scaling using the PS scaler tip (median: 3) than when using the conventional scaler tip (median: 5) (p < 0.05). Conclusions: In the in vitro study, using a slim scaler tip design causes less tooth substance loss compared to a wider scaler tip design. In the clinical study, less pain was observed compared than a wide (conventional) scaler tip design. © 2021, The Author(s).
Item Type: | Article |
---|---|
Funders: | UNSPECIFIED |
Uncontrolled Keywords: | Pain perception; Scaler tip design; Tooth substance loss; Tooth surface roughness; Ultrasonic scaler |
Subjects: | R Medicine > RK Dentistry |
Divisions: | Faculty of Dentistry |
Depositing User: | Ms. Juhaida Abd Rahim |
Date Deposited: | 25 May 2021 03:48 |
Last Modified: | 25 May 2021 03:48 |
URI: | http://eprints.um.edu.my/id/eprint/25978 |
Actions (login required)
View Item |