A novel and improved method of predicting hand grip strength in the adult Malaysian population

Kamarul, Tunku and Ahmad, Tunku Sara and Loh, William Y.C. (2006) A novel and improved method of predicting hand grip strength in the adult Malaysian population. Medical Journal of Malaysia, 61 (Spp. B). pp. 37-44. ISSN 0300-5283,

[img]
Preview
PDF
A_Novel_and_Improved_Method_of_Predicting_Hand.pdf

Download (1MB)
Official URL: http://www.ncbi.nlm.nih.gov/pubmed/17600991

Abstract

Hand grip strength measurement is a recognized part of hand function assessment. The standard measurement using the Jamar dynamometer and comparing these results to the recommended normal values suggested by the manufacturers of the Jamar was questioned as these values were based on Western population. A study comparing a novel method of predicting grip strength using our software was conducted on 25 normal subjects using the LIDO kinetic workset (Group A and B ). These results were then compared against our predictive software (Group A) and the expected values supplied together with the Jamar Dynamometer (Group B). In another group, 22 normal subjects were tested using the Jamar (Group C and D) and then matched against the predicted values using their recommended chart (Group C). The last group (Group D) was tested using the Jamar but the values attained were compared to the results from our software. In group A, the predictability of our predictive method was 100% (both R & L) as compared to (R = 64%, L = 68%) in group B, (R = 27.3%, L = 59.1%) in group C and (R = 81.8%, L = 86.4%) in group D. The differences between the predictability of both methods were statistically significant. The data collected using both the Jamar and the LIDO kinetic workset correlated well to the data from our software but not to the values suggested by the manufacturers of Jamar. We conclude that our method of predicting hand grip values are superior to that suggested by the manufacturers of dynamometers. The standard reference for hand grip strength provided by the manufacturers is less accurate in predicting the grip strength of our local population.

Item Type: Article
Funders: UNSPECIFIED
Additional Information: Corresponding Author: Tunku Kamarul Zaman, Department of Orthopaedic Surgery, Faculty of Medicine, Lembah Pantai, 50603 Kuala Lumpur, Malaysia
Uncontrolled Keywords: Hand Grip Strength; Normative Values
Subjects: R Medicine
Divisions: Faculty of Medicine
Depositing User: Nor Izzati Ab Razak
Date Deposited: 17 Jan 2012 06:23
Last Modified: 27 Aug 2020 00:58
URI: http://eprints.um.edu.my/id/eprint/2404

Actions (login required)

View Item View Item