Design optimisation of high sensitivity MEMS piezoresistive intracranial pressure sensor using Taguchi approach

Mohamad, Mazita and Soin, Norhayati and Ibrahim, Fatimah (2018) Design optimisation of high sensitivity MEMS piezoresistive intracranial pressure sensor using Taguchi approach. Microsystem Technologies, 24 (6). pp. 2637-2652. ISSN 0946-7076, DOI https://doi.org/10.1007/s00542-017-3699-8.

Full text not available from this repository.
Official URL: https://doi.org/10.1007/s00542-017-3699-8

Abstract

MEMS piezoresistive pressure sensors have been contemporarily used to measure intracranial pressure. Since an intracranial signal is of the pulsating type, the microsensor must be very sensitive to detect these changes. The sensitivity of the existing MEMS piezoresistive intracranial pressure sensors are in the range of 2 µV/V/mmHg to 0.17 mV/V/mmHg. Factors influencing the sensitivity and linearity of the sensor include the diaphragm thickness, the shape and placement of the piezoresistors, and the doping concentration. This paper will discuss the incorporation of these factors, which were tested to obtain higher sensitivity silicon-based piezoresistive intracranial pressure sensor, while maintaining the linearity of the sensor. In order to achieve this objective, the Taguchi robust design method of L27 orthogonal array was employed. The sensing outputs of these designs, with different combinations of factors were determined through simulations using COMSOL Multiphysics. The results indicated that the diaphragm thickness and perpendicular piezoresistors play important roles in the sensitivity performance of the MEMS piezoresistive intracranial pressure sensor. The findings also showed that the doping concentration of the piezoresistors have significant effect on the linearity performance of the sensor. Consequently, the design that consolidated the 3-turns (perpendicular) and 0-turn (parallel) meander shaped piezoresistors of 1017 cm−3 dopant concentration on a 2 μm diaphragm thickness was found to be the optimum design, with sensitivity of 0.1272 mV/V/mmHg and linearity of 99%. This design has been proven to be an improved version for the small diaphragm piezoresistive intracranial pressure sensor.

Item Type: Article
Funders: University Malaya Research Grant UMRG-AET (Grant number RP014B-13AET)
Uncontrolled Keywords: Comsol multiphysics; Design optimisation; Dopant concentrations; Doping concentration; Intra-cranial pressure; Piezoresistive pressure sensors; Sensitivity performance; Taguchi robust design
Subjects: R Medicine
T Technology > TK Electrical engineering. Electronics Nuclear engineering
Divisions: Faculty of Engineering
Depositing User: Ms. Juhaida Abd Rahim
Date Deposited: 21 May 2019 06:20
Last Modified: 21 May 2019 06:20
URI: http://eprints.um.edu.my/id/eprint/21268

Actions (login required)