Ibitoye, Morufu Olusola and Hamzaid, Nur Azah and Zuniga, Jorge M. and Hasnan, Nazirah and Wahab, Ahmad Khairi Abdul (2014) Mechanomyographic parameter extraction methods: An appraisal for clinical applications. Sensors, 14 (12). pp. 22940-22970. ISSN 1424-8220, DOI https://doi.org/10.3390/s141222940.
Full text not available from this repository.Abstract
The research conducted in the last three decades has collectively demonstrated that the skeletal muscle performance can be alternatively assessed by mechanomyographic signal (MMG) parameters. Indices of muscle performance, not limited to force, power, work, endurance and the related physiological processes underlying muscle activities during contraction have been evaluated in the light of the signal features. As a non-stationary signal that reflects several distinctive patterns of muscle actions, the illustrations obtained from the literature support the reliability of MMG in the analysis of muscles under voluntary and stimulus evoked contractions. An appraisal of the standard practice including the measurement theories of the methods used to extract parameters of the signal is vital to the application of the signal during experimental and clinical practices, especially in areas where electromyograms are contraindicated or have limited application. As we highlight the underpinning technical guidelines and domains where each method is well-suited, the limitations of the methods are also presented to position the state of the art in MMG parameters extraction, thus providing the theoretical framework for improvement on the current practices to widen the opportunity for new insights and discoveries. Since the signal modality has not been widely deployed due partly to the limited information extractable from the signals when compared with other classical techniques used to assess muscle performance, this survey is particularly relevant to the projected future of MMG applications in the realm of musculoskeletal assessments and in the real time detection of muscle activity.
Item Type: | Article |
---|---|
Funders: | UNSPECIFIED |
Uncontrolled Keywords: | Mechanomyographic signal; MMG parameters; muscle performance; isokinetic; isometric; electromyogram |
Subjects: | R Medicine |
Divisions: | Faculty of Engineering |
Depositing User: | Dr Mohd Faizal Hamzah |
Date Deposited: | 20 Jan 2016 10:41 |
Last Modified: | 26 Feb 2021 04:03 |
URI: | http://eprints.um.edu.my/id/eprint/15549 |
Actions (login required)
View Item |